Rail telecoms terms, at a glance
What each thing is, where the rules are, and what to order. In plain words.
- Access node
A node on the FTN/FTNx network that connects local users and equipment into the fibre network, fed from the main cable by a spur.
- BOP / distribution cabinet
A lineside box or cabinet where copper cables are terminated and pairs are broken out to local users (phones, signalling, equipment).
- Cable marker (Critchley)
A durable ID label clipped onto a cable so it can be identified on site: cable ID, type and route.
- Cable troughing
The concrete or composite channel units (with lids) laid along the lineside that the cables sit in. Sizes are named C/1/x, e.g. C/1/8, C/1/29, C/1/43.
- Core node
A main node on the FTN/FTNx network where transmission rings meet. FTNx core nodes house the DWDM equipment.
- DI-SAC cable
A heavily armoured, double-insulated fibre cable tough enough to lay on the ground without troughing.
- Induced voltage / immunisation
Voltage that appears on lineside cables because they run parallel to traction power. Immunisation is the set of measures that keep it within safe limits.
- Joint bay
A widened spot or pit off the main cable route where a cable joint closure sits, with room for the spare cable loop needed to make and re-make the joint.
- Manhole / cable chamber
An underground box on a buried or ducted route where cables can be pulled through, turned, or jointed, with a cover at the surface.
- ODF (optical distribution frame)
The frame or panel where fibre cables are terminated onto pigtails and connectors, so equipment can be patched in.
- Optical loss budget
The expected total light loss over a fibre section: cable attenuation plus every splice and connector, compared against what the equipment can tolerate.
- Pigtail
A short fibre tail with a factory-fitted connector on one end, spliced onto a cable fibre so it can plug into an ODF port.
- REB (relocatable equipment building)
A small prefabricated building beside the line that houses telecoms and signalling equipment. In FTN terms it's often an access node site.
- Screening conductor
An aluminium conductor run alongside telecoms cables and earthed at intervals, to reduce the voltage induced in them by AC traction.
- Sheath gap
A deliberate break in a cable's metal layers (armour, metallic sheath, moisture barrier), made with a gapping kit, so the metal is not one long continuous conductor.
- Spliceless joint
A joint position where the cable loops through the closure uncut, so fibres can be spliced into later without opening a new joint.
- SPT (signal post telephone)
A telephone at a signal (or other lineside point) that lets a driver or track worker speak directly to the signaller.
- Spur cable
A short cable branching off the main (trunk) fibre cable at a spur joint, to bring fibres into an access node such as an REB, cabinet or ATEH.
- Straight (through) joint
A joint where two lengths of the same main cable are spliced together, fibre to fibre, by colour and tube.
- UTX (under-track crossing)
A duct (or set of ducts) running under the tracks so cables can get from one side of the railway to the other without crossing over the rails.
- ZHLS cable
Cable with a sheath that gives off little smoke and no halogen gases if it burns. ZHLS = zero halogen, low smoke.