What is induced voltage and immunisation?
At a glance
Voltage that appears on lineside cables because they run parallel to traction power. Immunisation is the set of measures that keep it within safe limits.
Why: Too much induced voltage is a shock risk to staff and can damage equipment, so long copper and metallic cables must be designed to stay under the limits.
Where: Any long metallic cable in an electrified area, especially AC. Controls include limiting continuous length, sheath gaps, screening conductors and route position.
Where the rules are
- NR/GN/TEL/31106 cl 6.6how voltage is induced on lineside conductors
- NR/GN/TEL/31106 cl 7.2.1controlling hazardous potentials and the limits
- NR/GN/TEL/31106 cl 7.3factors affecting induced voltage
- NR/GN/TEL/31106 cl 7.4what immunisation means
- NR/GN/TEL/31106 cl 7.4.2limiting cable length (sheath gaps, sectioning)
On the drawing
Immunisation measures (sheath gaps, screening conductor earths) are shown on the copper drawings.
Also called: immunisation, longitudinal voltage, EMC from traction
Guidance in our words. Read the current issue of each standard before you design to it.