onestop

FTN survey specification

SP FTN (SU) 001

Survey of Cable Routes

Issue 10.2, Feb 2009 · FTN D&D specs & typical drawings

The FTN cable and cable route survey specification: what a surveyor must record about existing troughing, manholes, crossings and buildings, how to decide renovate versus new route or DI-SAC, and how to survey for fibre and copper cable lengths, joints and cabinets.

Clause map — what each clause deals with

1ImplementationSupersedes the previous issue; effective from date of issue.
2DisclaimerStandard Network Rail disclaimer.
3SupplyWhere to obtain copies.
4AbbreviationsLong abbreviation list including BOP, COSS, DI-SAC, FTE, GLT/SCT, OmniCom, SPT, TEPE, UFmX, UFtX, UTX, URX.
5PurposeWhy the survey is done, its two aims (condition/capacity and design input), renovate-vs-parallel-route philosophy, 90 mph line speed classification, long copper section conductor note.
6Scope of WorksDeliverable format, civils approvals, nominal section length, fragile cables, asbestos, utility clearances, full list of items to record, survey kit, and cable length allowances.
7Performance Requirements for Cable RoutesHow to decide new route vs renovation using the appendix flowcharts, lid tilting approach, DI-SAC as a route option, avoiding new UTXs, hollow sleepers banned.
7.1Use of OmniCom for SurveyingWhen and how track video can replace trackside survey, what to know beforehand, and the list of things it can be used to assess.
7.2Route FillLid lifting interval and T-pieces to assess spare capacity; what to note when route is fully buried.
7.3Replacement of Concrete ItemsCriteria for replacing or cutting damaged troughs and lids, photos of acceptable/unacceptable damage, missing/undersized/overlapping lids, upturned lids, locking lids for vandal areas.
7.4Lift and Relay, and Realignment of RoutePurposes of relaying/realigning and the parameters that apply when renovation is chosen.
7.4.1Lift and Relay RouteWhen to record lift and relay versus ballast clearance or ballast boards, based on surrounding ground/ballast levels.
7.4.2Realignment of RouteWhen to record realignment and when to consult the Territory Track Engineer about ballast shoulder.
7.4.3Route SupportRoute support on slopes, galvanised supports, ramped supports over catch pits, inspection of existing supports, photos required.
7.5Buried Troughing RoutesNo pulling or rodding through buried troughing; replacement with UTX where full; recording directly buried cables and crossings.
7.6Ballast BoardsWhen to record ballast boards, their construction, stacking height limits, Form A/B threshold, not combined with lift and relay.
7.7Route TransitionsRecording transition units where new route meets other troughing including imperial GLT.
7.8New Cable RoutePositioning of new route relative to track, datum plates, traction bonds, minimum/preferred rail distances, reduced clearance concession, triggers for new route (obsolete, asbestos, none, full).
7.9T-PiecesWhere T-pieces are needed (joint bays, BOPs, cabinets) and sizing.
7.10Machine Cut Concrete Troughing and LidsHow to count machine cut items.
7.11Ballast and Vegetation ClearanceDepth bands for ballast cover, other obstruction categories (shoulder, bank slip), and light/medium/heavy vegetation definitions, measured per route metre.
7.12ManholesGas check before entry; repairs, lid/frame replacement, materials, climbing aids, rebuild and renovate criteria, new manhole triggers, platform/UTX/URX manholes, keys, duct seals at buildings.
7.13Red/Green Zone WorkingRecording green vs red zone work, red zone prohibited, and which manhole works imply possession/night work.
7.14GRP, GRC, uPVCNon-concrete troughing for vertical, wall-top and parapet routes; asbestos cement replacement; recording existing wall routes and fixings.
7.15Retaining WallsWhen to record new, repaired or rebuilt retaining walls, construction standard and Form A/B threshold.
7.16Earthing Rods for Lineside CabinetsDo not open existing cabinets; earth rods only at DSL repeater cabinets, cabinet model compatibility.
7.17Concrete BasesREB base drawing, pre-cast bases for cabinets and BOPs, siting criteria to reuse tail cables, avoiding vandalism areas, when hard-standing is needed.
7.18Exchanges and Apparatus RoomsRecording occupied/free ducts into buildings, no allowance for future cables, diverse entries and sketches.
7.19Joint BaysParallel joint bays for copper joints and perpendicular joint bays or Stakka boxes for fibre joints, knockout sill protection, handrails for green zone, possession note.
7.20Routes Through StationsPlatform duct capacity needed, rodding and proving, test pulls, recording which ducts FTN uses, when a new platform duct route is justified and its manholes.
7.21Under Road Crossings / Level CrossingsAssess as for station ducts; when to record a new URX and subsidence reporting.
7.22Farm CrossingsUsing buried troughing at farm crossings or recording new buried troughing with double lids where vehicles cross.
7.23Under Track CrossingsPrefer under-track boring; when to record new 6-way or 4-way UTX; testing S-type UTXs with a test pull; sidings.
7.24Foot Crossing RoutesBuried troughing at foot crossings; otherwise as farm crossings.
7.25Routes Under Hard Surfaced Walkway or Through YardSame approach as farm crossings for buried routes under walkways and yards.
7.26Surplus Scrap Material, Recovery and DisposalRecording scrap by route metre, recovery via road, asbestos disposal.
7.27Restricted WorkingNoting tunnels, cuttings and restricted areas; tunnel entry only with possession and isolation.
7.28Route ObstructionsRecording removal of obstructions such as rails and sleepers.
7.29New Roads & Street Works ActRecording exact distances of manholes and ducts crossing roads, car parks and footpaths for NRSWA records.
7.30Cable Route Interfaces with NodesRecording GLT or duct interface at node sites per the 1001 to 1004 drawings.
8Cable Survey RequirementsParent clause for the fibre and copper cable surveys.
8.1Optical Fibre Cable SurveyEverything the surveyor records for fibre cables.
8.1.1GeneralList of fibre items to record: lengths, pull direction, joints, extra joints at crossings, sheath gaps, spurs, terminations, route separation, building entries.
8.1.2Centre to centre cable lengthsMaximise joint spacing, measure centre-to-centre and add section 6 allowances; cables terminate only at nodes, joints are not distribution points.
8.1.3Joint LocationsNominal fibre joint spacing and concession threshold, green zone siting, joint bays vs manholes, tunnel mouth joints, co-siting, spliceless joints near stations/level crossings, DI-SAC caveats.
8.1.4Sheath GapsWhy fibre sheaths are gapped; record positions per SP/FTN(D&D)/005 and 008.
8.1.5Core Node SitesCore nodes need physically diverse cables; meet SP/FTN(D&D)/008 resilience.
8.1.6Access Node Sites and Spur CablesSingle vs diverse spurs for SR and DR access nodes, deferral when approvals are missing, what to record for deferred and non-deferred spurs.
8.1.7Choice of Optical Fibre Cable TypeThe standard cable family (duct, armoured, ZHLS) and DI-SAC construction, where each may be used, subsurface station rule, refer to SP/FTN(D&D)/008 for selection.
8.1.8Provision for GSM-R Tunnel RepeatersFibre feed for tunnel and stand-alone repeaters: pulled fibre tubing and bundled fibre lengths, joint distance from tunnel mouth, BPE/O closure siting, DI-SAC restriction, trunking.
8.2Copper Cable SurveyEverything the surveyor records for copper cables.
8.2.1GeneralList of copper items to record: lengths, pull direction, joints, sheath gaps, cabinets and BOPs, tunnel termination boxes, building entries, electrification, earths, screening conductors, parallelism.
8.2.2Choice of Cable TypeTwo copper sheath types; refer to RT/E/PS/00015 for cable and SP/FTN(D&D)/009 for pair count and conductor size.
8.2.3Centre to centre cable lengthsMaximise joint spacing; copper measurement and the allowances to add for deviation, jointing and terminating.
8.2.4Joint LocationsNominal copper joint spacing and tolerance, joints only at drum ends, heat shrink closures, joint bays vs manholes, vandal protection, tunnel mouths, co-siting.
8.2.5Sheath GapsArmour gapping to limit induced voltage; record positions per SP/FTN(D&D)/005.
8.2.6Distribution Cabinets and BOPsSiting cabinets and BOPs to keep tail cables short and reuse existing tails, tail length limits, pre-tailed BOPs need joints either side, no through-jumpering.
8.2.7Details of ElectrificationRecord DC or AC, RR vs RC/BT, screening conductor presence, route height and distance from rail.
8.2.8Earth SystemsSiting rules for new earth farms and FTEs (distances from feeder stations, substations, sectioning cabins, other earths) and GT/TD INT100.
8.2.9ParallelismIdentify where AC feeders or National Grid lines run parallel for long distances; extra screening may be needed.
9Deployment of DI-SACDI-SAC treated as a route type; selected via flowchart; linked specs for installation, jointing and as-built.
9.1GeneralInstallation outcomes DI-SAC must achieve (service life, no obstruction, tamper resistance, straight line, trip hazard), positioning relative to track and troughing, mixing with good troughing.
10Deployment of DBS (Discarded)Sub-duct (DBS/SLD) no longer used as primary protection except short buried runs at crossings.
11ReferencesLists NR/SP/CIV/039, NR/GN/SIG/11210, NR/SP/OHS/011, NR/GN/SIG/11821, SP/FTN(D&D)/004, 005, 008, 009, NR/WI/CIV/143, GE/RT 8024, GI/RT 7008.
App ASurvey SpreadsheetNote on the Excel survey proforma, survey data sheet and Bill of Quantities; contractual BoQ takes precedence.
App BCable Route Renovation FlowchartDecision tree: existing route?, fibre only?, line speed over 90, cost per metre thresholds, leading to DI-SAC, new small SCT, new SCT or renovation.
App CRestricted Distance FlowchartDecision tree for routes closer than the minimum rail clearance: move route, hanger route, platform duct, new route or raise a technical query.
App DSCT Renovation Flow ChartDecision tree for renovating existing troughing: covered?, capacity?, trough replacement ratio, lid tilting.
App ERoute Cost Decision Flow ChartDecision tree estimating whether renovation cost exceeds the per-metre limit (fibre-only vs copper sections), lift and relay, support, realignment, clearance grades.
App FTroughing Lid Tilting ToolPhotographs of the lid tilting tool (images only, no text).