FTN design & development specification (D&D)
SP FTN (D&D) 010
Telecommunications Optical Fibre Cables
Issue 1, Feb 2002 · FTN D&D specs & typical drawings
Procurement spec for the FTN's standard 24-fibre singlemode cables (armoured, duct and ZHLS). Designers use it to check cable construction, tube and fibre colour codes, bend radius, attenuation figures, supply lengths and what the product acceptance tests prove.
Clause map — what each clause deals with
| 1 | Introduction | Purpose, scope and definitions for the cable spec. |
| 1.1 | Purpose | Procurement spec for PE and ZHLS sheathed fibre trunk cables, built on RT/E/PS/00014. |
| 1.2 | Scope | External singlemode G.652 cables; armoured, duct and ZHLS versions, fibre count by order. |
| 1.3 | Definitions | Definitions taken from BS 4727-3 Group 13. |
| 2 | Optical Fibres | Requirements on the fibre itself before cabling. |
| 2.1 | General | Step-index G.652 fibre, continuous with no splices, single source per contract. |
| 2.2 | Refractive Index Profile | Core/cladding make-up and the need to state group refractive index at both windows. |
| 2.3 | Coating Materials | Coating durability over 30 years, bond strength, strippability force limit, cure, hydrogen evolution, MSDS. |
| 2.4 | Proof Test | Proof strain level for 30-year life and the n-value to be stated. |
| 2.5 | Fibre Colour Coding | Table of fibre colours per tube (blue, orange, green, brown) and fibre numbering for up to 24 fibres. |
| 2.6 | Geometric Requirements | Limits on core/cladding non-circularity, concentricity, cladding and coating diameters. |
| 2.7 | Singlemode Waveguide Requirements | Mode field diameter, cut-off wavelength range, chromatic dispersion limits and PMD limits. |
| 2.8 | Attenuation Requirements | OTDR trace quality limits (steps, slope changes) and mandrel bend excess loss check. |
| 3 | Polyethylene Sheathed Armoured Cable | Construction of the standard armoured cable used in troughing, ducts and direct burial. |
| 3.1 | Service Life | Design life in troughing, duct or direct buried. |
| 3.2 | Strength Member | Non-metallic continuous central strength member and single-layer tube lay-up. |
| 3.3 | Tubes | Tube diameter, tube 1 red and last tube green, gel filling, no water-swellable tapes. |
| 3.4 | Fillers | Yellow fillers of tube size with fixed positions. |
| 3.5 | Core Binder | Core binder over tubes and fillers. |
| 3.6 | Inner Sheath | PE inner sheath material, minimum thickness and thickness ratio. |
| 3.7 | Armouring | Longitudinal steel/polymer laminate tape (may be corrugated), tape thickness, oversheath thickness, alternatives. |
| 3.8 | Sheath Marking | Legend content, repeat interval and optional sequential length marking. |
| 4 | Polyethylene Sheathed Duct Cable | Construction of the lighter single-sheath cable for buried ducts. |
| 4.1 | Service Life | Design life in buried duct. |
| 4.2 | Strength Member | Polymer-coated metallic central strength member. |
| 4.3 | Tubes | Same tube size, colours and filling rules as armoured cable. |
| 4.4 | Fillers | Yellow fillers. |
| 4.5 | Core Binder | Core binder. |
| 4.6 | Moisture Barrier | Longitudinal aluminium/polymer laminate with overlap and thickness requirements. |
| 4.7 | Oversheath | PE oversheath material and minimum thickness. |
| 4.8 | Sheath Marking | Duct cable legend and optional length marking. |
| 5 | ZHLS Sheathed Armoured Cable | Construction of the zero halogen low smoke armoured cable for stations and tunnels. |
| 5.1 | Service Life | Design life in troughing or duct. |
| 5.2 | Strength Member | Metallic or non-metallic CSM, coated if metallic. |
| 5.3 | Tubes | Tube size, colours and filling. |
| 5.4 | Fillers | Yellow fillers. |
| 5.5 | Core Binder | Core binder. |
| 5.6 | Moisture Barrier | Optional aluminium/polymer laminate moisture barrier. |
| 5.7 | Inner Sheath | ZHLS inner sheath bonded to the moisture barrier coating, thickness. |
| 5.8 | Armouring | Steel/polymer laminate tape with ZHLS oversheath. |
| 5.9 | Sheath Marking | ZHLS cable legend and length marking. |
| 6 | Product Acceptance Requirements: All Cable Types | The type tests a cable must pass for Product Acceptance. |
| 6.1 | Tensile Strength | Tensile test method, load related to cable weight, fibre strain limit. |
| 6.2 | Crush Strength | Crush test loads for armoured and duct cable with attenuation monitored. |
| 6.3 | Cable Bend | Bend cycling test and the maximum dynamic and static minimum bending radii as multiples of diameter. |
| 6.4 | Tube Kinking Test | Tube kink test cycles and statement of tube bend radius. |
| 6.5 | Resistance to Water Penetration | Water penetration test (not for ZHLS) with dye check. |
| 6.6 | Spark Test on the Oversheath | Spark test voltage and standard. |
| 6.7 | Sheath Thickness | How sheath thickness is measured on cut rings. |
| 6.8 | Ability to Strip Oversheath of Armoured Cables | Proving armour tape can be removed by hand without damaging the inner sheath. |
| 6.9 | Sheath Marking Abrasion Test | Abrasion test force and passes for legend legibility. |
| 6.10 | Peel Strength | Peel tests for polymer coating on tapes and sheath-to-tape adhesion. |
| 6.11 | Torsion | Torsion test for steel tape armoured cables, seam and sheath checks. |
| 6.12 | Impact Test | Impact test energy, impacts and checks for armoured cables. |
| 6.13 | Temperature Cycling Test | Full temperature cycling procedure: sample length, looped fibres on OTDR and power meter, cycle temperatures, allowed loss change and component movement limits. |
| 6.14 | Optical Attenuation | Attenuation measurement methods and the maximum dB/km in the 1310 and 1550 windows. |
| 6.15 | Cable Cut-off Wavelength | Cut-off wavelength test method. |
| 7 | Extra Acceptance Requirements for ZHLS Cables | Additional material and fire tests for ZHLS sheathed cable. |
| 7.1 | Insulation Resistance | Insulation resistance of ZHLS sheath material after water immersion. |
| 7.2 | Water Absorption | Water absorption limit for ZHLS compound. |
| 7.3 | Chemical Function Groups | Chemical groups (halogens, phosphorus, sulphur, nitrogen) excluded beyond trace level. |
| 7.4 | Smoke Emission | Smoke density test set-up and acceptance against GE/RC8505, flame spread and self-extinguishing. |
| 7.5 | Flammability | Bunched cable flame test and char height limit. |
| 8 | Production Tests | Routine tests on every production length and the certificates to accompany them. |
| 8.1 | All Cable Types | Which section 6 tests are run on all product and which need a stated frequency in the Quality Plan. |
| 8.2 | ZHLS Cables | Smoke and flammability tests run during ZHLS production. |
| 8.3 | Test Results | What the Certificate of Conformity must list per cable length (drum, type, length, refractive index, attenuation per fibre). |
| 9 | Miscellaneous | End sealing, drums, supply lengths and drum labels. |
| 9.1 | Sealing and Marking of Ends | Cable ends capped after test. |
| 9.2 | Drumming | Drum sizes to Def Stan 81-20, rolling direction arrow, outdoor storage period, battens, non-returnable drums. |
| 9.3 | Supply Lengths | Maximum and default supply lengths for duct and ZHLS cables versus armoured. |
| 9.4 | Labelling | Information required on the drum label. |
| 10 | Approvals | Product Acceptance and OFTEL approval requirements. |
| 10.1 | Product Acceptance | Product Acceptance route (RT/LS/P/029), test evidence and notification of design changes. |
| 10.2 | OFTEL Approval | Telecommunications Act approval and drum label statement. |
| 11 | Safety | Handling, preparation and testing to comply with HSWA 1974. |
| 12 | References | Railway and international standards referenced. |
| 12.1 | Railway Standards | RT/LS/P/029 and GE/RC8505. |
| 12.2 | International Standards | BS, BS EN, IEC, ITU-T and legislation referenced. |