onestop

FTN design & development specification (D&D)

SP FTN (D&D) 016

Specification for Identification and Labelling of Network Elements

Issue 2.3, Feb 2009 · FTN D&D specs & typical drawings

Defines how FTN cables, joints, cabinets, nodes and screening conductors get a unique identifier and how each is physically labelled. Used by routeworks contractors and designers to self-generate IDs that feed the as-built records.

Clause map — what each clause deals with

1IntroductionWhy the FTN needs a consistent identification and labelling scheme for its cables and equipment.
2AbbreviationsShort list of abbreviations used (BTS, DBS, DI-SAC, DSL, REB, UI, UTX, URX).
3GlossaryDefines node types, cabinets, fibre sections and sub-sections, network element, unique identifier.
4ScopeLists which key network elements need a unique identifier and label, and that IDs are captured per SP/FTN(D&D)/017.
5Identification of Key Network ElementsThe identifier scheme itself: node-based naming and the formats for each element type.
5.1General Approach to Identification of Key Network ElementsNodes act as reference points; intermediate elements are named from the nodes either side. Notes the exceptions.
5.2Format of Unique IdentifiersDifferent ID formats distinguish transmission nodes, cable infrastructure, screening conductors and route infrastructure.
5.2.1Format of Unique Identifiers for Transmission ElementsFour-character node IDs issued by Network Rail; how to tell a GSM-R co-located node from the ID style. Examples.
5.2.2Format of Unique Identifiers for Cable InfrastructureParent clause for cable, joint, cabinet, spur, stub and tunnel cable ID formats.
5.2.2.1Optical Fibre and Copper CablesThe cable ID pattern (prefix letter, two node IDs, discriminating letter), which nodes to reference, alphabetical ordering rule, worked examples.
5.2.2.2Optical Fibre Joints, Distribution Cabinets and Repeater CabinetsCable ID plus a two-character suffix for joints and cabinets; why numbering need not be consecutive; letters allowed and a range reserved for maintainer.
5.2.2.3Spur CablesDefines a spur cable and gives the SPUR-prefixed ID format with example.
5.2.2.4Stub CablesDefines copper stub cables (AC traction areas, branch line ends) and the STUB-prefixed ID format.
5.2.2.5Tunnel Termination Boxes and Tunnel CablesTunnel cable and termination box definition, kit part number, T-prefixed ID built from the cabinet ID, label sizes and placement on box and vertical C.
5.2.2.6GSM-R D-Mod CablesWithdrawn; D-Mod cables no longer used.
5.2.3Format of Unique Identifiers for Screening Conductors and EarthsScreening conductors and their earths are identified by Ordnance Survey grid references of the end points / master terminal.
5.2.4Format of Unique Identifiers for Non-key Network ElementsTwo-letter type code plus six-digit number for route sections, manholes, junctions, transition points, lid lifts, copper joints, DI-SAC and DBS features.
6Labelling of Network ElementsEvery key element must carry its ID on a permanent label; non-key elements need no label.
6.1Transmission NodesNode labelling is set by the ATEH/REB supplier and is outside routeworks contracts.
6.2Cable InfrastructureParent clause for labelling of cables, joints, terminations, cabinets, screening conductors and repeaters.
6.2.1Optical fibre and copper cablesWhere Critchley markers go on fibre and copper cables (building/cabinet entries, near joints and sheath gaps).
6.2.2Optical fibre JointsMarker on the closure entry port and splice tray marking with cable ID and tube number.
6.2.3Optical Fibre TerminationsSplice tray and pigtail label legend format at terminations, confirming splice direction with a light source, matching trays to the ODF connectivity drawing.
6.2.4Copper Distribution CabinetsParent clause for cabinet, vertical and pair labels.
6.2.4.1Cabinet labelCabinet ID label material, colour, size, font and positions outside above the door and inside the door.
6.2.4.2Vertical LabelsLabels for verticals A and B (size, fixing, content), the Tail Cables legend on vertical C and individual tail cable labels.
6.2.4.3Cable pair labelsManufacturer-supplied pair number labels, placement relative to DIN rail, pair numbering range per vertical.
6.2.5Copper Repeater CabinetsRepeater cabinets are labelled the same way as distribution cabinets; label usually already in place.
6.2.6Screening ConductorsCritchley marker at each earth connection point of a separate screening conductor.
6.2.7Screening Conductor EarthsMarker on the master terminal of each screening conductor earth.
6.2.8Tunnel Repeaters and In-Fill RepeatersID format for dedicated spur and link cables and joints feeding tunnel/in-fill repeaters, pigtail labelling reference, DISAC splicing note, when to seek technical clarification.
7ReferencesPoints to SP/FTN(D&D)/017 as-built records.
App AFTN Labelling Plan DrawingsList of DR/FTN(D&D)/030 to 034 labelling plan drawings (one cable, two cables, DSL areas, stub-ended systems, screening conductors).