FTN design & development specification (D&D)
SP FTN (D&D) 013
Specification for Lineside Cabinets Without Climate Control
Issue 1, Aug 2002 · FTN D&D specs & typical drawings
Product spec for the unpowered FTN distribution cabinet and its bolt-on DSL repeater housing: construction, security, environment, backplane layout, Mondragon VX verticals, through jumpers, labelling and acceptance tests. Useful when siting or specifying copper distribution cabinets.
Clause map — what each clause deals with
| 1 | Introduction | Background: cabinets to house copper terminations and DSL repeaters on the new FTN. |
| 2 | Abbreviations | Acronyms (DIN, DSL, ELR, GLT, MP, MTBF, SPT, WHD). |
| 3 | Glossary | Definitions of distribution cabinet, line powered, main cable, repeater housing, tail cable, through jumper, vertical. |
| 4 | Scope | Unpowered cabinets only; powered housings are under RT/E/PS/00028. |
| 5 | Cabinet Variants | The two products: the cabinet and the attachable repeater housing. |
| 5.1 | Distribution Cabinet | Definition of the standalone unconditioned cabinet. |
| 5.2 | DSL Repeater Housing | Definition of the end-mounted housing for up to five repeaters. |
| 6 | Construction | Physical build requirements for the cabinet. |
| 6.1 | General | Design life and compliance with lineside housing siting standard. |
| 6.2 | Materials | Preference for metallic superstructure. |
| 6.3 | Dimensions | Supplier sets size from contents; notional footprint given for planning. |
| 6.4 | Base Details | Compatibility with the small apparatus case concrete base and platform mounting. |
| 6.5 | Physical Protection | Anti-vandal measures: panel gaps, hidden hinges and LPS 1175 security rating. |
| 6.6 | Rodent Resistance | Materials and sealing against rodents. |
| 6.7 | Doors | Single front door, hinge side and opening angle. |
| 6.8 | Door Stays | Door stay and the wind load it must hold. |
| 6.9 | Cable Entry: Cable Clamps, Glanding Arrangements | Number and diameter range of main and tail cables to be retained, and pull-out force. |
| 6.10 | Locks and Handles | Multi-point lock with removable handle and provision for a cylinder lock. |
| 6.11 | Roof Profile | Roof shape to deter climbing and shed water and leaves. |
| 6.12 | Venting | Ventilation to limit condensation and the internal temperature limit with repeaters running. |
| 6.13 | Repeater Housing Access Panels | Removable end panels and void size for cables between cabinet and housing. |
| 7 | Environmental Requirements | Conditions the cabinet must survive. |
| 7.1 | Operational Environment | Exposed GB lineside locations, polluted/metallic dust and proximity to all traction types. |
| 7.2 | Ingress Protection | IP rating required. |
| 7.3 | Temperature and Humidity | Temperature and humidity range to be tolerated. |
| 7.4 | Vibration | Vibration amplitudes and frequency bands from passing trains, with a time profile per cycle. |
| 8 | Finish | Surface finish requirements. |
| 8.1 | General | Smooth rounded edges. |
| 8.2 | Paint | Paint to the protective treatments spec. |
| 8.3 | Colour | Standard cabinet colour. |
| 9 | Electrical Requirements | Earthing and bonding provisions. |
| 9.1 | Earthing Arrangements | Earth stud location and size. |
| 9.2 | Electrical Bonding | All metal parts bonded to the stud with specified earth wire. |
| 10 | Fittings | Three pair-count variants and how many VX terminations each gets on verticals A and B. |
| 10.1 | Cabinet Backplane | Removable backplane with marine ply area and three DIN rails named verticals A, B and C; backplane layout diagram. |
| 10.2 | Cable Terminations | Mondragon VX chosen for unconditioned sites; stranded tails need another termination; table of VX count per vertical by cable size. |
| 10.3 | Mounting of Cable Terminations | DIN rail type, terminations per rail, retainer positions, rail lengths for A/B/C. |
| 10.4 | Jumpers | A-to-B through jumpers fitted before shipping and swapped for A/B-to-C jumpers when circuits are distributed. |
| 10.5 | Jumper Management | Jumper field to manage A/B-to-C jumpers. |
| 10.6 | Cable Management | Storing slack per pair, fanning ten-pair groups and dressing cables. |
| 10.7 | Moisture Barrier Termination | Terminal block isolating the moisture barrier from earth with a removable link for testing. |
| 10.8 | Labelling | Cabinet, vertical and pair labelling. |
| 10.8.1 | Cabinet Label | Twelve-digit cabinet identifier format and the external and door labels. |
| 10.8.2 | Vertical Labels | Label holders on A and B for the cable identifier (nine-digit format) and the fixed label on C. |
| 10.8.3 | Cable Pair Labels | Pair number labels on each vertical, numbering direction and ranges. |
| 10.9 | Documentation: Document Holder | A4 holder inside the door. |
| 11 | Operational Performance History | Supplier evidence of reliability. |
| 11.1 | Experience in Railway Environment | Railway deployment history to be supplied. |
| 11.2 | MTBF | Minimum MTBF for the whole cabinet and supporting figures. |
| 12 | Maintenance | Maintainability and repair information. |
| 12.1 | Repair and Replacement of Cabinet Components | On-site replaceability and repair instructions. |
| 12.2 | Repair of Cabinet Finish | Instructions for scratches and graffiti. |
| 12.3 | Repeater Housing Access Panels | Maintenance checks on the access panels. |
| 13 | Product Acceptance | Acceptance route, sample and tests. |
| 13.1 | Product Acceptance Procedure | Product acceptance process and existing certificates. |
| 13.2 | Product Sample | Sample 50-pair cabinet with housing for termination trials and demonstration. |
| 13.3 | Product Acceptance Tests | Minimum tests to demonstrate. |
| 13.3.1 | Vibration Test | Fully fitted cabinet vibration test method and failure criteria. |
| 13.3.2 | Drop Test | Corner drop shock test and pass criteria. |
| 14 | Shipping | Packaging, lifting and instructions. |
| 14.1 | Packaging | Transit protection and what the packaging and door label must state. |
| 14.2 | Lifting Points | Lifting points, removable where they could snag. |
| 14.3 | Installation Instructions | Instructions supplied with each cabinet. |
| 15 | DSL Repeater Housing | Housing requirements, largely by reference to the cabinet sections. |
| 15.1 | General Requirements | List of cabinet sections that also apply to the housing. |
| 15.2 | Marine Ply Mounting Panel | Ply backplane and repeater screw spacing. |
| 15.3 | Dimensions | Housing sized from contents; holds up to five repeaters. |
| 15.4 | DSL Repeaters | Repeater unit size, clearance below each and the notional cabinet-plus-housing arrangement diagram. |
| 16 | References | Referenced standards. |
| App A | Concrete Base Drawing BRS-SC 32 | Placeholder for the base drawing; not reproduced in this copy. |