Rail Telecoms One Stop

Product specification

NR/PS/TEL/00014

Telecommunications Optical Fibre Cable (formerly RT/E/PS/00014)

Issue 4, April 2006 · Fibre design

Clause map — what each clause deals with

1PurposeProcurement spec for PE- and ZHLS-sheathed optical fibre trunk cables
2ScopeWhat cable types and fibre counts the spec covers
3Reference documentationReferenced standards (BS EN 187000 series, ITU-T G.652 and so on)
4DefinitionsDefinitions
5.1GeneralThe fibre type — singlemode to G.652
5.2Refractive Index ProfileRefractive index profile
5.3Coating MaterialsFibre coating materials
5.4Proof TestFibre proof testing for lifetime
5.5Fibre Colour CodingFibre colour coding tables
5.6Geometric RequirementsGeometric tolerances of the fibre
5.8Singlemode Waveguide RequirementsSinglemode waveguide parameters — mode field diameter, cut-off
5.9Attenuation RequirementsAttenuation requirements
6Polyethylene Sheathed Armoured CablePE-sheathed armoured cable construction — service life, strength member, tubes, fillers, binder, inner sheath, armour, marking
6.1Service LifeService life in trackside troughing
6.2Strength MemberCentral strength member (non-metallic)
6.3TubesLoose tubes — size and colour
6.7ArmouringSteel/polymer laminate armouring
6.8Sheath MarkingSheath marking legend
7Polyethylene Sheathed duct CablePE-sheathed duct cable construction
7.2Strength MemberMetallic strength member for duct cable
7.6Moisture BarrierMoisture barrier
8ZHLS Sheathed Armoured CableZHLS-sheathed armoured cable construction
9.1Tensile StrengthTensile strength test
9.2Crush StrengthCrush strength test
9.3Cable BendCable bend test
9.4Tube Kinking TestTube kinking test
9.5Resistance to Water PenetrationWater penetration test
9.7Sheath ThicknessSheath thickness
9.8Ability to Strip Oversheath of Armoured CablesStrippability of the oversheath
9.11TorsionTorsion test (armoured)
9.12Impact TestImpact test (armoured)
9.13Temperature Cycling TestTemperature cycling
9.14Optical AttenuationOptical attenuation measurement on every fibre
9.15Cable Cut-off WavelengthCable cut-off wavelength
10Extra Acceptance Requirements for ZHLS CablesExtra acceptance tests for ZHLS — insulation, water absorption, halogens, smoke, flammability
11Production TestsProduction tests and certificates of conformity
12.1Sealing and Marking of EndsSealing and marking cable ends
12.2DrummingDrumming requirements
12.3Supply LengthsSupply lengths
12.4LabellingDrum labelling
13.1Product AcceptanceProduct acceptance before supply
13.2OFCOM ApprovalOFCOM approval
14SafetySafety in handling and testing

Standards this one points to